Selecting a Power Supply for FDMs

Home > Support > FAQ > Selecting a Power Supply for FDMs

ITL does not ship power supplies with our FDMs, so you will need to choose a power supply to suit. The power supply you choose is important in maintaining the reliability and performance of the pump interfaces. We recommend you don't skimp on this aspect of your system.

If you want to buy a single standard power supply to run most FDMs, then:

One 15V DC, 1A, regulated power supply per FDM

will cover all except FDM115 (used in Asia-Pacific) and FDM170 (used in Europe).

FDMPower Supply
Part NumberName
FDM071Wayne/Gilbarco Current Loop15V DC, 1A, regulated
FDM082Passive Forecourt DistributionNone required
FDM093Tatsuno Partyline9-15V DC, 1A, regulated
FDM104Tokheim9-15V DC, 1A, regulated
FDM115NZ Protocol12V AC, 500mA
FDM126Email9-15V DC, 1A, regulated
FDM137ASCurrent Loop Active (Censtar)15V DC, 1A, regulated
FDM137HSCurrent Loop Active (HengShan)15V DC, 1A, regulated
FDM148PBCurrent Loop Passive9-15V DC, 1A, regulated
FDM159ASBennett/M300015V DC, 1A, regulated
FDM170Nuovo Pignone 4-wire24V DC, 1A, regulated
FDM192Active RS4859-15V DC, 1A, regulated
FDM203EPS9-16V DC, 1A, regulated
FDM225Logitron PumaLAN9-16V DC, 1A, regulated
FDM236HongYang 4-wire Current Loop15V DC, 1A, regulated

Power Supply Examples

Below are some examples of appropriate power supplies you can use, with links to the products on the element14 website. There are many other options and places to buy such power supplies. You don't need these exact manufacturers or products, but a similar standard of supply is needed. See the checklist below for more details.

Made By Part # Output Power Example Link Picture
XP Power AED36US15 15V, 2.4A element14
XP Power AED45US15 15V, 3A element14
XP Power DNR18US15 15V, 1.2A element14
Lambda JWS50-15/A 15V, 3.5A element14

Power Supply Checklist

Using more than one FDM?

If you have more than one FDM, you can use the same power supply for both, but you must add up the current requirement. For example, to run 2 x FDM071, you will need a 15V DC, 2A, regulated power supply. Or you could use two separate 1A power supplies.

Is a Higher Current Rating Ok?

Yes. When choosing a power supply, you may find power supplies with a higher current rating than is specified on this page (e.g. 2A instead of 1A).

The requirements listed here indicate the voltage required, and the minimum current for reliable operation.

Using the Wrong Supply:

Warranty Coverage and Problems

If you use the wrong power supply (not enough voltage or current, or unregulated) then:

In the past, it has been possible to get away with 12V supplies where 15V is required but this could change at any time depending on pump models or other factors out of our control.

Common Symptoms

If the FDM power supply is wrong, typical symptoms will be that all pumps on the loop don't work properly. Because power supply performance is affected by temperature, you should not assume that "because it has worked before it is Ok". The supply may have performed Ok previously but with a small margin for error.